Indesit TD 640 S (ICE) IX/IL Instruction for Use Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
GB
5
Burner and nozzle specifications
Table 1
Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal power
kW (p.c.s.*)
By-Pass
1/100
(mm)
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nomin. Ridot. (1) (mm) *** ** (mm)
Fast (R)
100 3,00 0,70 41 39 86 218 214 116 286
Semi Fast (S)
75 1,65 0.40 30 28 64 120 118 96 157
Auxiliary (A)
55 1,00 0,40 30 28 50 73 71 79 95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar-dry gas
** Propane P.C.S. = 50.37 MJ/kg.
*** Butane P.C.S. = 49.47 MJ/kg.
Natural P.C.S. = 37.78 MJ/m
3
(1) Only for appliances with the security device.
A
S
RS
TD 640 S IX/IL
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 27 28

Comments to this Manuals

No comments