GB
Table 1
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
20
17
25
28-30
20
35
37
25
45
Reduced Rapid (RR)
Semi Rapid (S)
Auxiliary (A)
Triple Crown (TC)
Supply
pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
100
75
55
130
2.60
1.65
1.00
3.25
NominalReduced
0.70
0.40
0.40
1.50
By-pass
1/100
(mm)
39
28
28
61
Nozzle
1/100
(mm)
Flow*
g/h
***
80
64
50
91
Flow*
l/h
110(Y)
96(Z)
71(X)
133(Z)
248
157
95
309
189
120
73
236
**
186
118
71
232
* A 15°C e 1013,25 mbar-dry gas
** Propane P. C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P. C.S. = 37.78 MJ/m
Burner and nozzle specifications
3
Nozzle
1/100
(mm)
Liquid Gas Natural Gas
PHN 942 T/IX/A
TC
S
RR
A