GB
7
! Ensure pipes do not touch any moving parts and is not compressed.
! Only use pipes and seals that comply with current national regulations.
Checking the tightness of the connection
! When the installation process is complete, check the pipe ttings for leaks
using a soapy solution. Never use a ame.
Operation of the appliance must be tasted by the installer before leaving.
Check all burners ames are blue in colour, stable and completely ignite at
both high and low ame settings with no appreciable yellow tipping, carbon
deposition, lifting, oating back or objectionable odour.
Test burners individually and in combination.
For other minor adjustments or if the appliance does not
perfrom correctly; contact Arisit Pty Ltd 1300 762 219
width
height
depth
Electrical
connections
Dimensions
(cm)
DATA PLATE
240 V
Hob 60 Hob 75 Hob 90
60
4,15
51
75
4,15
51
90
3,3
51