! Ensure pipes do not touch any moving parts and is not compressed.
! Only use pipes and seals that comply with current national regulations.
Checking the tightness of the connection
! When the installation process is complete, check the pipe ttings for leaks
using a soapy solution. Never use a ame.
Operation of the appliance must be tasted by the installer before leaving.
Check all burners ames are blue in colour, stable and completely ignite at
both high and low ame settings with no appreciable yellow tipping, carbon
deposition, lifting, oating back or objectionable odour.
Test burners individually and in combination.
For other minor adjustments or if the appliance does not
perfrom correctly; contact Arisit Pty Ltd 1300 762 219
width
height
depth
Electrical
connections
Dimensions
(cm)
DATA PLATE
240 V
Hob 60 Hob 75 Hob 90
60
4,15
51
75
4,15
51
90
3,3
51