Table of burner and nozzle specifications
Table 1 Liquid Gas Natural Gas
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Burner
Nominal Reduced (mm) (mm) *** ** (mm) (mm)
Fast
(Large)(R)
100 3.00 0.70 41 86 218 214 116 286 143 286
Semi Fast
(Medium)(S)
75 1.90 0.40 30 70 138 136 103 181 118 181
Auxiliary
(Small)(A)
55 1.00 0.40 30 50 73 71 79 95 80 95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
* At 15°C 1013 mbar-dry gas *** Butane P.C.S. = 49,47 MJ/Kg
** Propane P.C.S. = 50,37 MJ/Kg Natural P.C.S. = 37,78 MJ/m³
21
TECHNICAL DATA
Oven dimensions
(HxWxD)
34x38x39 cm
Volume
50 l
Useful
measurements
relating to the
oven
compartment
width 42 cm
depth 44 cm
height 23 cm
Power supply
voltage and
frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven compartment
has been opened, on the left-hand
wall inside the oven.
Electric Plate
Standard Ø 145 mm: 1500 W
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens. Standard EN
50304
Declared energy consumption for
Natural convection Class – heating
mode:

Static
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments -
2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments -
2002/96/EC.
1275/2008 Stand-by/ Off mode
Data plate, is located inside the flap or, after the
ovencompartment has been opened, on the left-hand
wall inside the oven.
SSS
SSS
KN1M117SA/RU
KNJ1G17A/RU