17
GB
Table of burner and nozzle specifications
Table 1 Liquid gas Natural gas
Thermal power
kW (p.c.s.*)
Capacity*
g/h
Burner Diameter
(mm)
Nominal Reduced
Bypass
1/100
(mm)
Nozzle
1/100
(mm)
*** **
Nozzle
1/100
(mm)
Capacity*
l/h
Rapid (Large)
(R)
100 3.00 0.70 41 86 218 214 116 286
Semi-rapid
(Medium) (S)
75 1.90 0.40 30 70 138 136 106 181
Auxiliary
(Small) (A)
55 1.00 0.40 30 50 73 71 79 95
Supply
pressure
Nominal (mbar)
Minimal (mbar)
Maximised (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50.37 MJ/kg
*** Butane P.C.S. = 49.47 MJ/kg
Natural P.C.S. = 37.78 MJ/m³
TECHNICAL DATA
Oven dimensions
(HxWxD)
32x43,5x40 cm
Volume
60 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 8.5 cm
Burners
may be adapted for use with any
type of gas shown on the data plate
Voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label
of electric ovens.
Regulation EN 50304
Declared energy consumption for
Natural convection Class –
heating mode
Static
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09
(Gas)
1275/2008 (Stand-by/ Off mode)
WARNING! The glass lid
can break in if it is heated
up. Turn off all the burners
and the electric plates be-
fore closing the lid.
S
S
R
A
KN6G11S/I
KN6G11SA/I
Comments to this Manuals