Table of burner and nozzle specifications
K6G21/R
K6G21S/R
KN6G21S/RO
WARNING! The glass lid can break
in if it is heated up. Turn off all the
burners and the electric plates before
closing the lid. *Applies to the models
with glass cover only.
Table 1 Liquid Gas Natural Gas
Burner Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Nominal Reduced (mm) (mm) *** ** (mm) (mm)
Fast
(Large)(R)
100 3.00 0.7 41 86 218 214 116 286 143 286
Semi Fast
(Medium)(S)
75 1.90 0.4 30 70 138 136 106 181 118 181
Auxiliary
(Small)(A)
55 1.00 0.4 30 50 73 71 79 95 80 95
Oven - 2.60 1.0 52 78 189 186 119 248 132 248
Grill - 2.30 - - 75 167 164 114 219 139 227
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18