5. Make sure the burner does not switch off when you
turn the knob from Max to Min quickly, or when you
open and close the oven door quickly.
! If the appliance is connected to liquid gas, the
regulation screw must be fastened as tightly as
possible.
Burner and Nozzle specifications
Table 1 Liquid gas Natural gas
Burner Thermal Power
kW (gross heat value)*
By-pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal Reduced (mm)
*** **
(mm)
Oven 2,60 1,00 49 78 189 186 119 248
Supply
pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar-dry gas
** Propane P.C.S. = 50.37 MJ/Kg
*** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m
3
DATA PLATE
Dimensions
width 43.5 cm
height 31 cm
depth 43.5 cm
Volume
58 l
Electrical
connections
voltage 220-230V ~ 50/60Hz
maximum power capacity 2800W
Gas features
category: II2H3+
thermal power:
2.60 (189 g/h - G30)
2.60 (186 g/h - G31)
This appliance conforms to the
following European Economic
Community directives: 73/23/EEC
dated 19/02/73 (Low Voltage)
and subsequent amendments -
89/336/EEC dated 03/05/89
(Electromagnetic compatibility)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments.
90/336/EEC dated 29.06.90 (Gas)
and subsequent amendments.
2002/96/EC
! Once this procedure is finished, replace the old
rating sticker with one indicating the new type of gas
used. This sticker is available from any of our Service
Centres.
! If the gas pressure is different from the
recommended pressure, a suitable pressure regulator
must be fitted to the inlet pipe in accordance with
current National Regulations.